The SITR bank contains a 16bit TriggerCard status and a 16bit Identifier.
Header
(five 32bit words)
Contents
(32bit word):
Bit | ||
---|---|---|
31______16 | 15______0 | |
status | identifier |
where:
status
- The BST Trigger System status; currently of no use to the offline analyst.
identifier
- The XILINX configuration file number (chronological)
The identifiers allow to traceback the channel mapping found in the data to a unique XILINX configuration having been in effect during the DAQ run. (An absent identifier denotes missing configuration and thus useless data output.) For detailed information on the respective mapping and interpretation of data refer to the configuration experts.
|
© by Hans Henschel, 27-aug-98, last revised: 19-jan-00